Service 04

Gas safety certificates in London

CP12 landlord certificates, usually same week. Every gas appliance and flue checked, and the record issued the same day.

Service overview

If you let a property with any gas appliance in it, you have a legal duty to have that appliance and its flue checked every twelve months by a Gas Safe registered engineer. The record that comes out of it is the CP12, and it is what agents, insurers and tenants ask for.

We do landlord certificates across London for single flats, portfolios and managing agents. Most are booked in the same week, and you get the record the same day rather than a fortnight later.

It is not the same job as a boiler service, though the two are sensibly done on one visit. A CP12 covers every gas appliance in the property and checks it is safe. A service is maintenance on one appliance.

We work across Greater London and north Surrey, including Croydon, Bromley, Sutton, Orpington and Wimbledon. Gas Safe engineers do every gas job. See the gallery, about us or get in touch.

Get a quote
WHAT'S INCLUDED
CP12 landlord gas safety certificate
Every gas appliance and flue tested
Gas tightness test
Flue flow and spillage testing
Ventilation and bonding checks
Same-day record issued
Portfolio and managing agent bookings

Send a message

Phone or WhatsApp is fastest for emergencies.

Jobs are fulfilled by independently vetted Gas Safe engineers. How we work

Signs you need gas safety certificate

  • You let a property that has any gas appliance in it
  • Your current certificate is inside two months of expiry
  • A letting agent or insurer has asked for a current CP12
  • You have taken on a property and cannot find the paperwork
  • You have added a gas appliance since the last check

What the law actually requires

The duty comes from the Gas Safety (Installation and Use) Regulations 1998. Every gas appliance and flue in a let property must be checked at intervals of no more than twelve months. The engineer has to be on the Gas Safe Register — since April 2009, when it replaced CORGI, there is no other legitimate route.

Two deadlines catch landlords out. The record has to reach the tenant within 28 days of the check, and new tenants must have it before they move in. Records have to be kept for two years. Missing either is a breach even where the appliances themselves were perfectly safe.

The two-month rule that stops the date creeping

Before 2018, having the check done early reset the clock, so a landlord who booked a fortnight early every year gradually lost weeks off the cycle. The 2018 amendment fixed that. You can now have the safety check carried out up to two months before the current certificate expires and keep the original expiry date.

In practice that means you can book at your convenience inside that window rather than waiting for the last possible week and hoping an engineer is free. For anyone running more than a couple of properties it is the difference between a manageable schedule and a scramble.

What gets checked

Every gas appliance: boiler, hob, cooker, fire, water heater. Each one gets a gas tightness test, a check that it is burning correctly, and a flue flow and spillage test to confirm combustion products are going outside rather than into the room.

We also check that ventilation is adequate and unobstructed, and that emergency control valves and pipework are sound and correctly bonded. Where an appliance fails we classify it, explain what that classification means, and tell you what needs doing to bring it back into use.

How the visit goes

01

Book it

Give us the address, the appliance list and tenant contact details. Most go in the same week.

02

Check every appliance

Tightness test, combustion check, flue flow and spillage test, ventilation and bonding.

03

Classify anything unsafe

If something fails you get told what the classification means and what it takes to put right.

04

Record issued same day

The CP12 comes to you the same day, in time to meet the 28-day duty to the tenant.

Standards this work is held to

Gas Safety (Installation and Use) Regulations 1998

The source of the landlord duty: every gas appliance and flue checked at intervals of no more than twelve months.

28-day rule

The record must be given to existing tenants within 28 days of the check, and to new tenants before they move in.

Two-year retention

Landlords must keep copies of gas safety records for two years.

2018 amendment

The check can be done up to two months early without losing the original expiry date, so the annual cycle does not drift.

Gas safety certificate: common questions

Every twelve months. The Gas Safety (Installation and Use) Regulations 1998 set the maximum interval, and it applies to every gas appliance and flue in a let property.
It is the landlord gas safety record — the document produced when a Gas Safe registered engineer checks the gas appliances in a let property. CP12 is the old form number and the name stuck.
Yes. Since the 2018 amendment you can have it done up to two months before expiry and keep the original expiry date, so booking early no longer shortens your cycle.
Within 28 days of the check for an existing tenant. A new tenant must have it before they move in.
Two years.
Yes. The duty covers every gas appliance, not just the boiler. A hob alone still needs checking.
Yes, and most landlords do. They are different jobs, but doing them on one visit saves a second call-out.
It gets classified according to how serious the fault is, and unsafe appliances are disconnected with your permission. You get told exactly what the classification means and what is needed to bring the appliance back into use.